A-A-51301A
The elastic binding” shall be stitched to the cover opening, so that the opening shall measure approximately nine inches in diameter when manually stretched to its extreme opening without breaking. The stitching shall be free of defects. The elastic binding and the elastic band shall be of a suitable width and sufficient elasticity and strength to secure the cover to the shoe with a snug fit during use, without deterioration of the cover.
Thread breaks, skip, and run-off shall be overstitched not less than 1/2 inch. Skipped stitches or thread breaks shall be repaired. The thread tension shall be maintained, so that there shall not be any loose or tight stitching, and the lock shall be embedded in the materials sewn together. All thread ends shall be trimmed to a maximum length of one quarter inch. The cover shall not contain any metal, spot, stain, non-specified hole, abraded area, tear, cut mend, patch, scorch, or needle chew.
Type 2. The footwear cover shall be a disposable, nonconductive, nonskid, nonwoven synthetic material, without tears or flaws in the material, or excessive threads. The cover shall be moisture resistant with an elasticized top which allows the cover to hold firmly to the shoe by means of the elastic binding and band. The cover shall have an opening to allow for “one size fits all” with a secure, soft, and comfortable fit.
Workmanship. The operating room footwear cover shall be free from defects which detract from its appearance or impair its serviceability.
Unit. Package (PG).
Type 1. Package (PG). One package of 100 pairs of footwear covers, as specified, constitutes one unit.
Type 2. Package (PG). One package of 300 pairs of footwear covers, as specified, constitutes one unit.
Quality Assurance Provisions.
Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein,” unless disapproved by the Government. The
For Parts Inquires call Parts Hangar, Inc (727) 493-0744